Research
Epitranscriptomics & Cancer Adaptation : A.David

Activities

Our research work focuses on the contribution of post-transcriptional mechanisms on cancer cell adaptation, in particular RNA epigenetic & translational control.

More..

Zotero public

Added by JPPOUGET
Group name EquipeJPP
Item Type Journal Article
Title Robustness of Breast Margins with Volumetric Modulated Arc Therapy without a Six-Degrees-of-Freedom Couch: A Dosimetric Evaluation
Creator Prunaretty et al.
Author Jessica Prunaretty
Author Nicolas Mir
Author Anaïs Tilhac
Author Maureen Gouillou
Author David Azria
Author Pascal Fenoglietto
Author Céline Bourgier
Abstract In our hospital, a TrueBeam linear accelerator and the PerfectPitch 6-degrees-of-freedom (6-DOF) couch (Varian), with 7 mm margins, are used for volumetric modulated arc therapy (VMAT) of breast cancer (BC). This study tested whether a 3-degrees-of-freedom (3-DOF) couch, i.e., without rotation compensation (such as the Halcyon couch), affected dose metrics. A total of 446 daily extended cone beam computed tomography (CBCT) data of 20 patients who received VMAT for BC were used to recalculate the treatment plans with the session registration (6-DOF) and a simulated matching with 3-DOF. The initial plan provided significantly better coverage for internal mammary chain and clavicular lymph node clinical target volumes (CTVs) than the 6-DOF and 3-DOF CBCT plans. The volumes receiving 110% of the prescribed dose (V110%) were increased for all CTVs with the 6-DOF and 3-DOF CBCT plans, but the difference was significant only for the breast/chest wall CTV (p < 0.05; paired samples t-test). Protection of the heart and lungs was comparable among plans. The dose volume histograms based on the 6-DOF and 3-DOF data were similar for CTVs and organs at risk. Therefore, with a 7 mm margin, VMAT and a 3-DOF couch can be used for BC treatment without any compromise in delivery accuracy.
Publication Journal of Clinical Medicine
Volume 12
Issue 3
Pages 862
Date 2023-01-21
Journal Abbr J Clin Med
Language eng
DOI 10.3390/jcm12030862
ISSN 2077-0383
Short Title Robustness of Breast Margins with Volumetric Modulated Arc Therapy without a Six-Degrees-of-Freedom Couch
Library Catalog PubMed
Extra Number: 3 PMID: 36769509 PMCID: PMC9917561
Tags breast cancer, clinic, first-last-coresponding, last, planning margins, VMAT
Date Added 2023/11/23 - 12:48:18
Date Modified 2024/12/15 - 03:56:54
Notes and Attachments PubMed entry (Attachment)
Texte intégral (Attachment)


© Institut de Recherche en Cancérologie de Montpellier - 2011 - Tous droits réservés - Mentions légales - Connexion - Conception : ID Alizés